LPJ(600V) Class J 伊顿bussmann熔断器
电流:1-600A
电压:600Vac
认证:UL、CE
产品型号:LPJ-9SPI,LPJ-90SPI,LPJ-8SPI,LPJ-80SPI,LPJ-7SPI,LPJ-70SPI,LPJ-6SPI,LPJ-60SPI,LPJ-600SPI,LPJ-5SP,LPJ-5-6/10SP,LPJ-50SPI,LPJ-500SPI,LPJ-4SP,LPJ-45SPI,LPJ-450SPI,LPJ-4-1/2SP,LPJ-40SPI,LPJ-400SPI,LPJ-3SP,LPJ-35SPI,
全国热线

021-51083699-829
181-1739-4269

在线咨询

产品详情



Ultimate Protection 600Vac/300Vdc, 1-600A, Dual Element, Time-Delay Fuses
 
Class J dual element, current-limiting, time-delay fuses available with optional open fuse indication on select ratings (see data sheets).
Time-delay – 10 seconds (minimum) at 500% of rated current.
__________________________________________________________________________
 
Available With Indication
Description:
Dual-element, time-delay fuse; 10 seconds (minimum) at 500% rated amps. Now available with optional indication on select ratings
 
Ratings:
Volts: 600Vac (or less); 300Vdc (or less)
Amps: 1-600A
IR: 300kA RMS Sym. 100kA dc
 
Agency Information: CE, UL Listed - Special Purpose*, Guide JFHR, File E56412, CSA Certified (200k AIR) Class J per CSA-22.2 No. 248.8, Class 1422-02, File 53787.
 
General Information:
• True dual-element fuses with a minimum 10 second timedelay at 500% overload.
• Long time-delay minimizes needless fuse openings due to temporary overloads and transient surges.
• Can often be sized for back-up protection against motor burnout from overload or single-phasing if other overload protective devices fail.
• High interrupting rating to safely interrupt overcurrents up to 300,000A.
• High degree of current limitation due to the fast speed-ofresponse to short-circuits.
• Faster response to damaging short-circuit currents than mechanical overcurrent protective devices.
• Reduces let-through thermal and magnetic forces in order to protect low withstand rated components.
• Proper sizing provides “no damage” Type “2” coordinated protection for NEMA and IEC motor control in accordance with IEC Standard 947-4-1.
• Dual-element fuses have lower resistance than ordinary fuses so they run cooler.
• Lower watts loss reduces power consumption.
• Unique dimensions assure that another class of fuse with a lesser voltage rating, interrupting rating or current-Iimiting ability cannot be substituted.
• Space-saving package for equipment down sizing.
 
COOPER BUSSMANN (EATON‘S)
LPJ-SP系列
 
     LPJ-SP 系列产品型录(1-60A)
     LPJ-SP 系列产品型录(70-600A)
     Product change notice - fuse labeling   (产品更改通知—标签更改)
     UL Card  (File)
     CSA Card (File)
     CE
 
 
Ultimate Protection 600Vac/300Vdc, 1-600A, Dual Element, Time-Delay Fuses
 
Class J dual element, current-limiting, time-delay fuses available with optional open fuse indication on select ratings (see data sheets).
Time-delay – 10 seconds (minimum) at 500% of rated current.
__________________________________________________________________________
 
Available With Indication
Description:
Dual-element, time-delay fuse; 10 seconds (minimum) at 500% rated amps. Now available with optional indication on select ratings
 
Ratings:
Volts: 600Vac (or less); 300Vdc (or less)
Amps: 1-600A
IR: 300kA RMS Sym. 100kA dc
 
Agency Information: CE, UL Listed - Special Purpose*, Guide JFHR, File E56412, CSA Certified (200k AIR) Class J per CSA-22.2 No. 248.8, Class 1422-02, File 53787.
 
General Information:
• True dual-element fuses with a minimum 10 second timedelay at 500% overload.
• Long time-delay minimizes needless fuse openings due to temporary overloads and transient surges.
• Can often be sized for back-up protection against motor burnout from overload or single-phasing if other overload protective devices fail.
• High interrupting rating to safely interrupt overcurrents up to 300,000A.
• High degree of current limitation due to the fast speed-ofresponse to short-circuits.
• Faster response to damaging short-circuit currents than mechanical overcurrent protective devices.
• Reduces let-through thermal and magnetic forces in order to protect low withstand rated components.
• Proper sizing provides “no damage” Type “2” coordinated protection for NEMA and IEC motor control in accordance with IEC Standard 947-4-1.
• Dual-element fuses have lower resistance than ordinary fuses so they run cooler.
• Lower watts loss reduces power consumption.
• Unique dimensions assure that another class of fuse with a lesser voltage rating, interrupting rating or current-Iimiting ability cannot be substituted.
• Space-saving package for equipment down sizing.
 
Features and Benefits
• Separate overload and short-circuit elements provide time delay for sizing of high inrush loads linked with Class J current limitation.
• Selective coordination ratio of 2:1 (within Low-Peak fuse family) prevents electrical shutdowns from extending beyond the failed circuit.
• Series combination ratings with branch circuit breakers allows broad range of coverage, independent of breaker manufacturer.
 
Typical Applications
• Power Panelboards
• Branch Circuit Breaker Panelboard Mains
• Machinery Disconnects
• Industrial Control
 
Catalog Numbers (Amps)
 
 
*Meets all performance requirements of UL Standard 248-8 for Class J fuses.
**Available with optional permanent replace fuse indication. To order, place “I” at end of catalog number. As below table.
 
Catalog Numbers (With optional permanent replace fuse indication)










 

热门产品

扫码关注

关注微信

bet3365娱乐场手机版|bet亚洲官方网站

XML 地图 | Sitemap 地图